logos

ISOKINETIC STACK AND AIR EMISSION MONITORING

Alam Hijau equipped with approved methods and equipments to conduct isokinetic stack and air emission monitoring those recognize by Department of Environment, Malaysia.

Full Std. C Environmental Quality (Clean Air) Regulation, 1978 Part V, Air Impurities

Test Parameter Unit Standard C
Dust g/Nm3 0.4 g/Nm3
NOX g/Nm3 2.0 g/Nm3
HF g/Nm3 0.1 g/Nm3
HCl g/Nm3 0.4 g/Nm3
Cl2 g/Nm3 0.2 g/Nm3
H2SO4 g/Nm3 0.2 g/Nm3
Cu g/Nm3 0.1 g/Nm3
Zn g/Nm3 0.1  g/Nm3
As g/Nm3 0.025 g/Nm3
Sb g/Nm3 0.025 g/Nm3
Pb g/Nm3 0.025 g/Nm3
Cd g/Nm3 0.015 g/Nm3
Hg g/Nm3 0.01 g/Nm3

Test Method
MS1596:2003 / US EPA (Environmental Protection Agency) Test Methods

Methods Description
MS1596:2003 Determination of Concentration and flow of particulate Matter in Flue Gas
USEPA Method 7E Determination of Nitrogen Oxide from stationary sources
USEPA Method 8 Determination of Sulfuric Acid from stationary sources
USEPA Method 11 Determination of Hydrogen Sulfide from stationary sources
USEPA Method 26A Determination of Chlorine Gas, Hydrogen Chloride & Hydrofluoric Acid  from stationary sources
USEPA Method 29 Determination of metals from stationary sources
USEPA Method 23 Dioxin and Furan

 

alamhijau   alamhijau   alamhijau

alamhijau   alamhijau   alamhijau

 

 

 

DARK SMOKE OBSERVATION

DARK SMOKE FOR GENERATOR SET/BOILER

Environmental Quality (Clean Air) Regulation, 1978 Part IV, Dark Smoke.

Smoke emissions darker than Ringelman Chart No. 1,
Cannot Exceed 5 minutes in 1 hour.

Methods Description
BS 2742C Dark Smoke Observation using Ringelmann Smoke Chart