logos

AMBIENT AIR QUALITY MONITORING

Alam Hijau conducts Ambient Air Quality Monitoring services and has extensive experience in ambient air sampling and analysis. Ambient air characteristics standards are designed to protect human health, with an adequate margin of safety, including sensitive populations and individuals suffering from respiratory disease in order to comply with Malaysian Recommended Air Quality Guidelines.

No Parameter Methodology Sampling Technique
1 Total Suspended Particulate (TSP) AS 2724.3 High Volume Sampler
2 Particulate Matter <10 Micron (PM10) USEPA IO-2.1 High Volume Sampler With Size Selective Chamber
3 Nitrogen Dioxide (NO2) ISC 408 Impinger with Chemical Liquid
4 Sulfur Dioxide (SO2) ISC 704 A Impinger with Chemical Liquid

 

Recommended Malaysian Air Quality Guidelines (Ambient Standards)

Pollutant Averaging Time Guideline Concentration
(ppb) (µg/m3)
Primary Guidelines 1
Nitrogen Oxides (NOX) 1 hour 170 320
Sulphur Dioxide (SO2) 10 min
1 hour
24 hour
190
130
40
500
350
105
Carbon Monoxide (CO) 1 hour
8 hour
30,000
9,000
35,000
10,000
Ozone (O3) 1 hour
8 hour
100
60
200
120
Total Suspended Particulates (TSP) 24 hour
1 year
-
-
260
90
Respirable Dust (PM10) 24 hour
1 year
-
-
150
50
Lead 3 months - 1.5
Secondary Guidelines 2
Dust fall 1 year 133 mg/m2/day
Notes:
1. Protection of Public Health
2. Prevention of nuisance and damage to the environment